Schluter DITRA Peel & Stick Uncoupling Membrane
Shipping & Delivery
- $13.95 Flat Rate shipping for orders under $500 (Other options at checkout)
- Same-day shipping cut-off time for ground orders for CD stock items is 3:00 PM ET
- Same-day shipping cut-off time for expedited orders for CD stock items is 12:00 PM ET
- Shipping time is calculated by business days. Weekends do not count.
- For Freight Items See Policy Here
Schluter DITRA-PS Peel & Stick Uncoupling Membrane
Schluter DITRA-PS brings the benefits of the original DITRA membrane; the multi-tasking underlayment that provides uncoupling, load distribution, waterproofing, and vapor management for durable tile installations; to a convenient peel and stick format.
Features
- Pressure-sensitive adhesive (PSA) which bonds the membrane to the substrate, eliminating the need for thin-set mortar
- Significantly reduces installation time, labor costs, and cleanup
- Offers the same core functions as the original DITRA
- Uncoupling, waterproofing*, vapor management, and load support to ensure a long-lasting tile installation
- Suitable for use with a wide range of substrates, including concrete, OSB (including Advantech), and plywood
- It can also be installed over various floor coverings
- Comes in three sizes: 7.75 sq ft (0.72 m2) sheet and 110sqft (10m2) and 269sqft (25m2) rolls
- Membrane thickness: 1/8" - 3.5 mm
- 7.75 sq ft sheet dimensions: 3'2-3/4" X 2'5" = 7.75 SF
- 110sqft roll dimensions: 3'2-3/4" X 34'3/4" = 110 SF
- 269sqft roll dimensions: 3'2-3/4" X 83'4" = 269 SF
How To Use
Please note: All substrates must be clean, even, and load bearing. Bond inhibiting surfaces must be removed prior to the application of DITRA-PS. For complete installation guidelines and warranty criteria, please refer to the Schluter-DITRA Installation Handbook
- Simply remove the transparent release film from the PS membrane to expose the layer of adhesive, and embed it into the substrate
- Apply peel and stick membrane to the floor, fleece/adhesive side down. Solidly embed the matting into the substrate using a float, screed trowel, or DITRA-ROLLER
- Abut adjacent sheets and align the studs on the top of the matting to make subsequent heating cable installation easier
- No thin-set required to install membrane means a faster and easier installation
- The membrane can easily be repositioned until pressure is exerted
- If the application area requires a membrane that meets or exceeds the requirements of ANSI A118.10, please refer to thin-set versions of DITRA
Maintenance
Storage: DITRA-PS features a UV sensitive pressure-sensitive adhesive that should not be stored in places with prolonged exposure to direct sunlight. The PSA is also temperature sensitive and should be stored in a frost-free environment 41 - 86 °F (5 - 30 °C). If product is exposed to conditions outside of recommended temperature range, product shall be re-acclimated to range for a minimum of 24 hours. The PSA is not water soluble and is free of solvents.